Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.800
Filtrar
1.
J Indian Soc Pedod Prev Dent ; 42(1): 37-45, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38616425

RESUMO

PURPOSE: The purpose of this clinical trial was to assess and compare the clinical outcomes of Bioflx crowns (BFCs) with stainless steel crowns (SSCs) in primary molars (PMs). MATERIALS AND METHODS: This prospective split-mouth randomized controlled clinical trial was conducted between March 2022 and June 2023. Thirty-eight patients (17 females and 21 males) with a mean age of 5.21 years participated in this study. Each child (n = 38) received both SSC and BFC. Clinical and radiographic follow-up was performed at baseline, 3, 6, and 12 months using the modified United States Public Health System scoring criteria to evaluate various parameters. RESULTS: At the 3 and 6 months' follow-up, no significant difference was observed between the two groups. However, at 1-year follow-up, a statistically significant difference (P < 0.05) was evident in the frequency between the two groups for the criteria of crown retention after cementation and anatomic form of the crown, indicating a preference for SSC over prototype 1 BFC. CONCLUSION: The 12-month results indicate that BFC performed similarly to the established SSC for the restoration of PMs providing better esthetics.


Assuntos
Boca , Aço Inoxidável , Criança , Feminino , Masculino , Humanos , Pré-Escolar , Estudos Prospectivos , Coroas , Dente Molar
2.
PLoS One ; 19(4): e0301799, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625846

RESUMO

BACKGROUND: Marginal fit significantly impacts the long-term success of dental restorations. Different pattern fabrication methods, including hand-waxing, milling, or 3D printing, may affect restorations accuracy. The effect of porcelain firing cycles on the marginal fit of metal-ceramic restorations remains controversial, with conflicting findings across studies. PURPOSE: The aim was to evaluate the potential effects of multiple porcelain firings (3, 5, 7 cycles) as well as pattern fabrication method (conventional hand-waxing, milling, and 3D printing) on the marginal adaptation of 3-unit implant-supported metal-ceramic fixed partial dentures. It was hypothesized that neither the wax pattern fabrication method nor repeated ceramic firings would significantly affect the marginal adaptation of metal-ceramic crowns. METHODS: In this in-vitro study, 30 Cobalt-Chromium alloy frameworks were fabricated based on pattern made through three techniques: conventional hand-waxing, CAD-CAM milling, and CAD-CAM 3D printing (n = 10 per group). Sixteen locations were marked on each abutment to measure the vertical marginal gap at four stages: before porcelain veneering and after 3, 5, and 7 firing cycles. The vertical marginal gap was measured using direct microscopic technique at ×80 magnification. Mean vertical marginal gap values were calculated and two-way ANOVA and Tukey's post hoc tests were used for inter-group comparisons (α = 0.05). RESULTS: The 3D printing group showed significantly lower (P<0.001) mean vertical marginal gaps (60-76 µm) compared to the milling (77-115 µm) and conventional hand-waxing (102-110 µm) groups. The milling group exhibited a significant vertical gap increase after 3 firing cycles (P<0.001); while the conventional (P = 0.429) and 3D printing groups (P = 0.501) showed no significant changes after 7 firing cycles. Notably, the vertical marginal gap in all groups remained below the clinically acceptable threshold of 120 µm. CONCLUSION: CAD-CAM 3D printing provided superior marginal fit compared to CAD-CAM milling and conventional hand-wax pattern fabrication methods. The impact of porcelain firing on the mean marginal gap was significant only in the milling group. All three fabrication techniques yielded clinically acceptable vertical marginal adaptation after repeated firings. Additive manufacturing holds promise to produce precise implant-supported prostheses.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Impressão Tridimensional , Prótese Parcial Fixa , Ligas Metalo-Cerâmicas , Planejamento de Prótese Dentária , Coroas
3.
J Dent ; 144: 104987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580056

RESUMO

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Teste de Materiais , Porcelana Dentária/química , Humanos , Dente Suporte , Cerâmica/química , Propriedades de Superfície , Materiais Dentários/química , Adaptação Marginal Dentária , Ligas de Cromo/química
4.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(2): 135-141, 2024 Apr 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38597073

RESUMO

Zirconia crown has been widely used in the field of prosthodontics. Traditional zirconia exhibits excellent mechanical properties but lacks translucency. The introduction of transparent zirconia significantly enhances its aesthetic performance. In clinical applications, factors affecting the aesthetic results of full zirconia crown should be comprehensively considered, and the most suitable restoration should be chosen. Additionally, clinicians need to design appropriate tooth preparation dimensions and methods based on an individual patient's actual situation. During the clinical bonding process of zirconia, proper surface treatment of the tooth and restoration is essential. The selection of suitable adhesives is crucial for achieving optimal bonding strength and aesthetics.


Assuntos
Estética Dentária , Dente , Humanos , Coroas , Zircônio
5.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(2): 249-255, 2024 Apr 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38597085

RESUMO

Complicated crown root fracture is a serious combined fracture of the enamel, dentin, and cementum in dental trauma. The treatment method is complicated. During the procedure, the condition of pulp, periodontal, and tooth body should be thoroughly evaluated, and a multidisciplinary approach combined with sequential treatment is recommended. This case reported the different treatment and repair processes of one case of two affected teeth after complicated crown root fracture of upper anterior teeth, including regrafting of broken crown after flap surgery at the first visit, direct resin repair to remove broken fragments, and pulp treatment and post-crown repair at the second visit. After 18 months of follow-up, the preservation treatment of the affected teeth with complicated crown root fracture was achieved. Therefore, fragment reattachment and post-crown restoration are feasible treatment options for children with complicated crown root fracture.


Assuntos
Fraturas dos Dentes , Raiz Dentária , Criança , Humanos , Incisivo/lesões , Coroa do Dente/lesões , Fraturas dos Dentes/terapia , Exposição da Polpa Dentária/terapia , Coroas
6.
J Mech Behav Biomed Mater ; 154: 106536, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38579394

RESUMO

OBJECTIVE: This study aimed to conduct a comparison of trueness and physical and surface properties among five distinct types of additive manufactured (AM) zirconia crowns and zirconia crowns produced using the subtractive manufacturing (SM). MATERIAL AND METHODS: Zirconia crowns were fabricated using five distinct techniques, each varying in the method of slurry transfer and photocuring source. Each experimental group utilized either one of the four digital light processing (DLP)-based techniques (DLP spreading, DLP spreading gradation, DLP vat and DLP circular spreading) or the stereolithography (SLA)-based technique (SLA spreading). The control (CON) group employed SM. To assess accuracy, trueness was measured between the scan and reference data. To analyze the physical properties, voids were examined using high-energy spiral micro-computed tomography scans, and the crystal structure analysis was performed using X-ray diffraction (XRD). Surface roughness was assessed through laser scanning microscopy. RESULTS: Differences in the trueness of internal surfaces of crowns were found among the groups (P < 0.05). Trueness varied across the measurement surfaces (occlusal, lateral, and marginal) in all the groups except for the DLP spreading gradation group (P < 0.05). Voids were observed in all AM groups. All groups showed similar XRD patterns. All AM groups showed significantly greater surface roughness compared to the CON group (P < 0.001). CONCLUSION: The AM zirconia crowns showed bubbles and a rougher surface compared to the SM crowns. All groups exhibited typical zirconia traits and trueness levels within clinically acceptable limits, suggesting that current zirconia AM techniques could be suitable for dental applications.


Assuntos
Desenho Assistido por Computador , Coroas , Microtomografia por Raio-X , Zircônio , Propriedades de Superfície
7.
Int J Oral Maxillofac Implants ; 39(2): 243-253, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657217

RESUMO

PURPOSE: To validate an innovative 3D volumetric method of evaluating tissue changes proposed by Lee et al in 2020 by comparing the results of this method-in which the scanned peri-implant surfaces were transformed, visualized, and analyzed as 3D objects-to the results reported by an existing method based on calculation of the mean distance between measured surfaces. The null hypothesis was that there was no statistically significant difference between the two methods. Additionally, the present study evaluated peri-implant tissue changes 5 years after single implant placement in the esthetic zone. MATERIALS AND METHODS: Both methods were applied to 11 oral implant site casts (6 maxillary central incisor sites, 5 maxillary lateral incisor sites) taken from 11 patients at crown placement and at follow-up examinations 5 years later. The methods are based on digital workflows in which the reference and 5-year casts are scanned and the resulting STL files are superimposed and analyzed for three regions of interest (mesial papilla, central area, and distal papilla). The volumetric changes reported by the Lee et al method and the mean distance method were calculated and compared using the Spearman rank correlation coefficient (P < .01) and the Wilcoxon signed-rank test (P < .05). RESULTS: The correlation between the two sets of measurements was very high (Spearman rank correlation coefficient = 0.885). The new volumetric method indicated a mean volume loss of 2.82 mm3 (SD: 5.06), while the method based on the measurement of mean distance showed a mean volume loss of 2.92 mm3 (SD: 4.43; Wilcoxon signed-rank test result: P = .77). No statistically significant difference was found. The two methods gave equivalent results, and the null hypothesis was accepted. CONCLUSIONS: The new volumetric method was validated and can be considered a trustworthy tool.


Assuntos
Implantes Dentários para Um Único Dente , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Maxila/cirurgia , Maxila/anatomia & histologia , Feminino , Implantação Dentária Endóssea/métodos , Modelos Dentários , Coroas , Masculino , Adulto , Incisivo/anatomia & histologia
8.
Int J Oral Maxillofac Implants ; 39(2): 278-285, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657220

RESUMO

PURPOSE: To evaluate and compare the difference in retention between implant-supported restorations with and without surface modification of the implant abutments. MATERIALS AND METHODS: A total of 30 patients with singletooth implants were restored with cement-retained (Multilink N, Ivoclar) restorations using titanium base abutments (Variobase, Straumann) and randomly assigned surface modifications. Group 1 used nonmodified abutments, group 2 used sandblasted abutments, and group 3 used sandblasted abutments followed by an application of metal primer. All patients were recalled for a baseline examination 6 months after crown placement. The pull-out strength and intergroup distribution of mean pull-out strength were assessed. To assess differences between the three groups, intergroup statistical comparison of continuous variables was done using one-way ANOVA with Tukey correction for multiple group comparisons. RESULTS: The results of the intergroup mean pull-out strength distribution revealed that the distribution of mean ± SD pull-out strength in group 1, group 2, and group 3 were 220.79 ± 94.23, 488.64 ± 84.12, and 705.46 ± 112.75 Ncm, respectively. CONCLUSIONS: Sandblasting followed by the application of metal primer produced the highest retention of porcelain-fused-to-metal (PFM) crowns to titanium base abutments, followed by sandblasting alone, with the least retention being observed with no surface treatment.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Metacrilatos , Propriedades de Superfície , Titânio , Humanos , Feminino , Masculino , Titânio/química , Pessoa de Meia-Idade , Coroas , Adulto , Análise do Estresse Dentário
9.
Eur J Med Res ; 29(1): 254, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659074

RESUMO

BACKGROUND: Yttrium-stabilized zirconia (YSZ) and alumina are the most commonly used dental esthetic crown materials. This study aimed to provide detailed information on the comparison between yttrium-stabilized zirconia (YSZ) and alumina, the two materials most often used for esthetic crowns in dentistry. METHODOLOGY: The ground-state energy of the materials was calculated using the Cambridge Serial Total Energy Package (CASTEP) code, which employs a first-principles method based on density functional theory (DFT). The electronic exchange-correlation energy was evaluated using the generalized gradient approximation (GGA) within the Perdew (Burke) Ernzerhof scheme. RESULTS: Optimization of the geometries and investigation of the optical properties, dynamic stability, band structures, refractive indices, and mechanical properties of these materials contribute to a holistic understanding of these materials. Geometric optimization of YSZ provides important insights into its dynamic stability based on observations of its crystal structure and polyhedral geometry, which show stable configurations. Alumina exhibits a distinctive charge, kinetic, and potential (CKP) geometry, which contributes to its interesting structural framework and molecular-level stability. The optical properties of alumina were evaluated using pseudo-atomic computations, demonstrating its responsiveness to external stimuli. The refractive indices, reflectance, and dielectric functions indicate that the transmission of light by alumina depends on numerous factors that are essential for the optical performance of alumina as a material for esthetic crowns. The band structures of both the materials were explored, and the band gap of alumina was determined to be 5.853 eV. In addition, the band structure describes electronic transitions that influence the conductivity and optical properties of a material. The stability of alumina can be deduced from its bandgap, an essential property that determines its use as a dental material. Refractive indices are vital optical properties of esthetic crown materials. Therefore, the ability to understand their refractive-index graphs explains their transparency and color distortion through how the material responds to light..The regulated absorption characteristics exhibited by YSZ render it a highly attractive option for the development of esthetic crowns, as it guarantees minimal color distortion. CONCLUSION: The acceptability of materials for esthetic crowns is strongly determined by mechanical properties such as elastic stiffness constants, Young's modulus, and shear modulus. YSZ is a highly durable material for dental applications, owing to its superior mechanical strength.


Assuntos
Óxido de Alumínio , Coroas , Ítrio , Zircônio , Ítrio/química , Zircônio/química , Óxido de Alumínio/química , Humanos , Teoria Quântica
10.
Shanghai Kou Qiang Yi Xue ; 33(1): 71-75, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583028

RESUMO

PURPOSE: To evaluation the effect of modified triangular flap-secondary healing (MTF-S) on the treatment of mandibular impacted wisdom teeth with full or partial bone impaction. METHODS: A total of 207 patients with mandibular impacted wisdom teeth were selected in Shaoxing Stomatological Hospital from June 2022 to June 2023. Among them, 86 patients had completely impacted wisdom teeth (group A), and 121 patients had partially impacted wisdom teeth (group B). All patients had bilateral impacted wisdom teeth. One of the wisdom teeth was removed first and was sutured with triangular flap-primary healing (TF-P). The other wisdom tooth was removed two weeks later and was sutured with MTF-S. Patients in groups A and B were divided into two subgroups based on suture methods, with TF-P used for group A1 and B1, and MTF-S used for groups A2 and B2. Perioperative indicators, including surgical time, root loss rate, and completeness of extraction sockets were recorded; Postoperative complications of four groups, including pain, swelling, and limited mouth opening were compared. SPSS 22.0 software package was used for statistical analysis. RESULTS: The surgical time of group A1, A2, B1 and B2 was (17.69±3.28), (18.22±3.06), (12.37±3.72) and (12.64±4.13) minutes, respectively. The surgical time of group A1 and A2 was significantly longer than that of group B1 and B2 (P<0.05). Seven days after surgery, the VAS scores of group A1, A2, B1 and B2 were (1.17±0.34), (0.93±0.29), (0.48±0.15) and (0.76±0.21), respectively. The VAS scores of group B1 and B2 were lower than those of group A1 and A2, and group A2 was lower than group A1 and B2 was higher than group B1 group(P<0.05). On the 1st day, 3rd day, and 7th day after surgery, the swelling degree in group A1 was greater than that in group B1, and the swelling degree in group B1 was greater than that in group A2 and B2(P<0.05); while the limitation of mouth opening mouth in group A2 and B2 was lower than that in group A1 and B1, and the limitation of opening mouth in group B2 was lower than that in group A2(P<0.05). CONCLUSIONS: Compared with partially impacted wisdom teeth, the extraction of completely impacted wisdom teeth has a longer surgical time. For completely impacted wisdom teeth, MTF-S is beneficial for reducing postoperative pain, swelling and mouth opening limitations. For partially impacted wisdom teeth, MTF-S is beneficial for reducing postoperative swelling and mouth opening limitations, but the effect is not significant in reducing patient pain.


Assuntos
Dente Serotino , Dente Impactado , Humanos , Dente Serotino/cirurgia , Extração Dentária/efeitos adversos , Extração Dentária/métodos , Dente Molar , Dente Impactado/cirurgia , Coroas , Dor Pós-Operatória
11.
BMC Oral Health ; 24(1): 337, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491485

RESUMO

BACKGROUND: The selection of post-core material holds significant importance in endodontically treated teeth, influencing stress distribution in the dental structure after restoration. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) glass fiber post-core possesses a better adaptation for different root canal morphologies, but whether this results in a more favorable stress distribution has not been clearly established. MATERIALS AND METHODS: This study employed finite element analysis to establish three models of post-core crown restoration with normal, oversized, and dumbbell-shaped root canals. The three models were restored using three different materials: CAD/CAM glass fiber post-core (CGF), prefabricated glass fiber post and resin core (PGF), and cobalt-chromium integrated metal post-core (Co-Cr), followed by zirconia crown restoration. A static load was applied and the maximum equivalent von Mises stress, maximum principal stress, stress distribution plots, and the peak of maximum displacement were calculated for dentin, post-core, crown, and the cement acting as the interface between the post-core and the dentin. RESULTS: In dentin of three different root canal morphology, it was observed that PGF exhibited the lowest von Mises stresses, while Co-Cr exhibited the highest ones under a static load. CGF showed similar stress distribution to that of Co-Cr, but the stresses were more homogeneous and concentrated apically. In oversized and dumbbell-shaped root canal remnants, the equivalent von Mises stress in the cement layer using CGF was significantly lower than that of PGF. CONCLUSIONS: In oversized root canals and dumbbell-shaped root canals, CGF has shown good performance for restoration of endodontically treated teeth. CLINICAL RELEVANCE: This study provides a theoretical basis for clinicians to select post-core materials for residual roots with different root canal morphologies and should help to reduce the occurrence of complications such as root fracture and post-core debonding.


Assuntos
Vidro , Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Coroas , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Desenho Assistido por Computador , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Resinas Compostas/química , Teste de Materiais , Estresse Mecânico
12.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532413

RESUMO

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Assuntos
Coroas , Cimentos Dentários , Zircônio , Humanos , Torque , Teste de Materiais , Dente Suporte , Titânio , Parafusos Ósseos , Análise do Estresse Dentário , Falha de Restauração Dentária
13.
Int J Prosthodont ; 37(7): 89-98, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498861

RESUMO

PURPOSE: To assess crown die trueness using additive manufacturing (AM) based on intraoral scanning (IOS) data and compare it with stone models. MATERIALS AND METHODS: Crown dies with four finish line types- equigingival shoulder (SAE), subgingival shoulder (SAS), equigingival chamfer (CAE), and subgingival chamfer (CAS)-were incorporated into a reference model and scanned with a coordinate measurement machine (CMM; n = 1 scan). Trios4 (3Shape) scans generated a second reference dataset (IOS; n = 10 scans). Using scans, crown dies were produced with two different 3D printers (MAX UV385 [Asiga] and NextDent 5100 [3DSystems]; n = 10 per system). Stone dies were created from conventional impressions (n = 10). Specimens were digitized with a laboratory scanner (E4, 3Shape). Trueness was evaluated with Geomagic Control X (3DSystems). Data analysis was done using Shapiro-Wilk, Levene, ANOVA, and t tests (α < .05). RESULTS: All crown dies fell within the clinically acceptable trueness range (150 µm). IOS exhibited significantly lower (P < .05; Δ ≤ 21.7 µm) or similar trueness compared to stone models. Asiga dies demonstrated similar and NextDent significantly lower marginal trueness than IOS (P < .05; Δ ≤ 57.3 µm). Most AM margin areas had significantly lower trueness than stone (P < .001; Δ ≤ 57.2 µm). Asiga outperformed NextDent (P < .001). Shoulder trueness surpassed chamfer in optical scans (P = .01). Finish line design and gingiva location did not have a significant impact on AM and stone models (P > .05). CONCLUSIONS: Combining IOS and AM achieves clinically acceptable crown die trueness for single molar teeth. The choice of AM device is critical, with Asiga outperforming NextDent. Finish-line design has an impact on optical scans. Finish-line design and marginal gingiva location have little effect on AM trueness.


Assuntos
Desenho Assistido por Computador , Dente , Fluxo de Trabalho , Coroas , Técnica de Moldagem Odontológica , Imageamento Tridimensional
14.
Int J Prosthodont ; 37(7): 127-131, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498864

RESUMO

PURPOSE: To evaluate and compare the fracture resistance and elastic modulus of 3D-printed post and core systems and fiber posts and composite cores. MATERIALS AND METHODS: Endodontic treatment was performed on 30 mandibular premolars, and post space preparation was performed. The teeth were then randomly divided into two groups (n = 15 per group): the 3D-printed (3DP) group and the fiber post and composite core (FPC) group. In the FPC group, fiber posts (Cytec Blanco 43.604, Hahnenkratt) were bonded with resin cement (RelyX U200, 3M), and the composite core dimension was standardized with a silicone index. In the 3DP group, the impression of the post space for each specimen was taken with pattern resin (Pattern Resin, GC America), and the coronal core was produced with the same silicone index. The impressions of the posts and cores were scanned, and then the custom post and core structures were fabricated from permanent crown resin material (Permanent Crown Resin, Formlabs) with a 3D printer (Form3B, Formlabs). Specimens were subjected to load tests with a universal testing machine (M500-25AT, Testometric). After fracture occurred, the fracture force and elastic modulus were calculated. The data were analyzed by independent sample t test (α = .05) Results: There was no statistically significant difference between the two groups in terms of peak fracture force (P = .626) and elastic modulus (P = .125), and no catastrophic root fractures were observed in either group. CONCLUSIONS: The fracture resistance of endodontically treated teeth was not significantly influenced by the post material. 3D-printed, custom-made resin posts were as effective as fiber glass posts with regard to fracture resistance.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/química , Coroas , Vidro/química , Cimentos de Resina/química , Silicones , Impressão Tridimensional , Dente não Vital/terapia , Análise do Estresse Dentário
15.
Int J Prosthodont ; 37(7): 79-88, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498860

RESUMO

PURPOSE: To compare the accuracy of 12 different dental restorations fabricated with milling or 3D-printed molds and robotically controlled casting. MATERIALS AND METHODS: Twelve dental restorations (11 inlays and onlays and 1 crown) were made per restoration type, one per each of the 12 different teeth models (total of 24 restorations). On each tooth preparation, two restorations were manufactured using different CAD/ CAM techniques: (1) milling and (2) robotically controlled casting and 3D-printed molds. In addition, twolayer restorations were manufactured with 3D-printed molds. The marginal and internal gaps were evaluated at 120 points per restoration based on micro-CT 3D imaging. Internal gaps were evaluated using a replica technique with silicone. RESULTS: Median values (interquartile ranges) for marginal gaps, middle internal gaps, and central internal gaps were significantly lower for 3D-printed mold restorations (44.3 [65.4] µm, 95.4 [96.2] µm, and 104.6 [78.1] µm) compared to milled restorations (58.4 [93] µm, 145.9 [85.8] µm, and 138.6 [65.7] µm). Internal gaps in the 3D-printed mold group were 6% to 51% smaller than in the milled group. CONCLUSIONS: The accuracy of restorations fabricated with 3D-printed molds may be preferable compared to milled restorations, except in the case of crown restoration. However, additional studies with a larger number of samples and different types of restorations are needed to confirm the results.


Assuntos
Desenho Assistido por Computador , Adaptação Marginal Dentária , Projetos Piloto , Restaurações Intracoronárias , Coroas , Impressão Tridimensional , Planejamento de Prótese Dentária/métodos
16.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 56-61, 2024 Feb 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38475951

RESUMO

OBJECTIVES: This study aimed to evaluate the influence of ceramic type and thickness on the masking ability and final aesthetic effects of chairside machinable all-ceramic crowns. METHODS: Six kinds from three types chairside machinable ceramic materials (IPS e.max CAD HT/MT/LT, IPS Empress LT, and VITA Suprinity HT/T) in shade A2 were fabricated to slice specimens into 1.0, 1.5, and 2.0 mm-thick sections (n=10). The color parameters of the specimens against black and white tiles and four resin substrates (A2, A4, B3, and C4 shade) were measured with a spectrophotometer. The translucency parameter (TP) was calculated using color parameters measured over standard white and black backgrounds. The color differences (ΔE) were calculated between there substrate shades (A4, B3, C4 ) and A2 shade (control group). Two-way analysis of variance (ANOVA) was performed on the TP values. The two va-riables were ceramic type and ceramic thickness. Three-way ANOVA was used to determine the effects of ceramic materials, ceramic thickness, and substrate shades on the ΔE values, followed by Tukey test for multiple comparisons (α=0.05). RESULTS: Ceramic type, ceramic thickness, and substrate shade significantly affected the ΔE values (P<0.001). The L* and b* values of the specimens increased with increasing ceramic thickness, except in substrate A2, whereas the ΔE values decreased. The color difference of all 1.0 mm-thick specimens or all specimens over the substrates C4 shade exceeded the clinically acceptable threshold (ΔE>3.3). CONCLUSIONS: The masking ability of chairside machinable all-ceramic crowns is influenced by ceramic type and thickness, and ceramic material. The thickness of ceramic less than 2.0 mm cannot mask the gray shade abutment.


Assuntos
Porcelana Dentária , Estética Dentária , Cor , Teste de Materiais , Cerâmica , Coroas
17.
J Clin Pediatr Dent ; 48(2): 102-110, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38548639

RESUMO

This randomized, controlled clinical trial compares the clinical performance of glass-fibre and resorbable polylactic acid (PLA) intracanal posts used to restore carious primary incisors in young patients. The study sample includes 180 primary upper central incisors of 90 children aged 3 to 4 years. All patients were randomly divided into two equal groups of 45 children who received PLA and glass-fibre (GFP) intracanal posts. The clinical assessment of incisor restorations was carried out immediately upon completion and at months 3, 6 and 12 according to the following criteria: anatomical form, marginal adaptation, surface roughness, marginal pigmentation, colour match, secondary caries and contact point. The Gingival Index (GI), the Bleeding Index (Cowell modification; mBI), and bite force (BF) were measured. At the 3-month follow-up, the occlusal BF of patients who received PLA posts was higher than the baseline; the GI and mBI scores were lower, by contrast (p < 0.05). This tendency was even more pronounced 6 and 12 months after the restoration. The incidence of side effects or symptoms (apical inflammation, cervical fracture, loosening of the crown) after the PLA posts was significantly lower than after the GFP (p < 0.05). No statistically significant differences were present between the two groups with respect to colour matching, anatomical form, marginal adaptation, marginal pigmentation, surface roughness, occlusal contact and secondary caries. Based on the results, applying PLA intracanal posts and cyanoacrylate to residual anterior crowns in young children can improve their gingival health, reduce side effects, and increase the likelihood of successful restoration.


Assuntos
Cárie Dentária , Técnica para Retentor Intrarradicular , Criança , Humanos , Pré-Escolar , Resinas Compostas/uso terapêutico , Incisivo , Coroas , Poliésteres , Cárie Dentária/tratamento farmacológico , Falha de Restauração Dentária , Restauração Dentária Permanente/métodos
18.
J Clin Pediatr Dent ; 48(2): 189-195, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38548649

RESUMO

Children with dentinogenesis imperfecta require restorative or prosthodontic treatment to minimize the aesthetic and functional impact of the condition. This clinical case report describes the oral rehabilitation procedure in a 12-year-old patient with dentinogenesis imperfecta type II using nanoceramic resin crowns fabricated with Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) technology and the patient's progression over eight years. This minimal intervention approach enabled functional and aesthetic reestablishment along with tooth wear prevention. The result simplified an extensive prosthetic procedure and facilitated an affordable rehabilitation for the young patient while providing excellent long-term outcomes.


Assuntos
Dentinogênese Imperfeita , Criança , Humanos , Dentinogênese Imperfeita/terapia , Coroas , Desenho Assistido por Computador , Planejamento de Prótese Dentária
19.
Clin Oral Investig ; 28(4): 220, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492074

RESUMO

OBJECTIVES: This in vitro study aims to compare the fracture resistance of three CAD/CAM materials used in endocrown restoration of interproximal defects in maxillary premolars. MATERIALS AND METHODS: 45 maxillary premolars extracted as part of orthodontic treatment were included. Following standardized root canal treatment, all teeth were prepared into Mesial-Occlusal (MO) cavity types. The samples were then randomly divided into three groups: LD [repaired with lithium disilicate glass ceramics (IPS e.max CAD)], VE [treated with polymer-infiltrated ceramics (Vita Enamic)], and LU [repaired with resin-based nanoceramics (Lava Ultimate)]. Axial static loading was applied using a universal testing machine at 1 mm/min until fracture, and fracture resistance and failure modes were recorded. RESULTS: Regarding Fracture Resistance Values (FRVs), the LD group exhibited significantly higher values than the other two groups, VE (P = 0.028) and LU (P = 0.005), which showed no significant difference (P = 0.778). On the other hand, regarding failure modes, the LD group had a higher prevalence of irreparable fractures compared to the other two groups, VE (P < 0.001) and LU (P < 0.001), which showed no significant difference. CONCLUSIONS: Although lithium disilicate glass ceramics exhibited higher FRVs, they had a lower repair probability. In contrast, polymer-infiltrated ceramics and resin-based nanoceramics contributed to tooth structure preservation. CLINICAL RELEVANCE: For maxillary premolars with interproximal defects following root canal treatment, resin ceramic composites are recommended for restoration to enhance abutment teeth protection.


Assuntos
Cerâmica , Coroas , Dente Pré-Molar , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química , Resinas Compostas/química , Polímeros , Desenho Assistido por Computador , Análise do Estresse Dentário , Falha de Restauração Dentária
20.
J Hum Evol ; 189: 103512, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461589

RESUMO

Neanderthal anterior teeth are very large and have a distinctive morphology characterized by robust 'shovel-shaped' crowns. These features are frequently seen as adaptive responses in dissipating heavy mechanical loads resulting from masticatory and non-masticatory activities. Although the long-standing debate surrounding this hypothesis has played a central role in paleoanthropology, is still unclear if Neanderthal anterior teeth can resist high mechanical loads or not. A novel way to answer this question is to use a multidisciplinary approach that considers together tooth architecture, dental wear and jaw movements. The aim of this study is to functionally reposition the teeth of Le Moustier 1 (a Neanderthal adolescent) and Qafzeh 9 (an early Homo sapiens adolescent) derived from wear facet mapping, occlusal fingerprint analysis and physical dental restoration methods. The restored dental arches are then used to perform finite element analysis on the left central maxillary incisor during edge-to-edge occlusion. The results show stress distribution differences between Le Moustier 1 and Qafzeh 9, with the former displaying higher tensile stress in enamel around the lingual fossa but lower concentration of stress in the lingual aspect of the root surface. These results seem to suggest that the presence of labial convexity, lingual tubercle and of a large root surface in Le Moustier 1 incisor helps in dissipating mechanical stress. The absence of these dental features in Qafzeh 9 is compensated by the presence of a thicker enamel, which helps in reducing the stress in the tooth crown.


Assuntos
Homem de Neandertal , Humanos , Adolescente , Animais , Incisivo , Simulação por Computador , Análise de Elementos Finitos , Coroas , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...